Parametric studies of mixed convective fluid flow around cylinders of different cross‐sections

dc.contributor.authorOlayemi Adebayo Olalekan
dc.contributor.authorIbitoye Emmanuel Segun
dc.contributor.authorObalalu Adebowale Martins
dc.contributor.authorAl-Farhany Khaled
dc.contributor.authorJolayemi Samsudeen Temidayo
dc.contributor.authorJinadu Abdulbaqi
dc.contributor.authorAjide Favour Tomisin
dc.contributor.authorAdegun Kayode Isaac
dc.date.accessioned2023-07-14T13:20:55Z
dc.date.available2023-07-14T13:20:55Z
dc.date.issued2023-05-22
dc.description.abstractA numerical study of mixed convective heat transfer in a lid‐driven square enclosure containing a hot elliptic cylinder is conducted. The impacts of the Grashof number (103 ≤ Gr ≤ 106), Reynolds number (1.0 ≤ Re ≤100), cylinder tilt angle (0° ≤ ϕ ≤ 90°), and aspect ratio (1.0 ≤ AR ≤ 3.0) have been examined for a fluid of Pr of 0.71. The horizontal enclosure walls are insulated, while its vertical walls are restricted to a nonvarying temperature Tc, whereas a sinusoidal temperature of Th + ∆T sin(πxL/ ) is imposed on the wall of the elliptical cylinder. The governing equations are solved using COMSOL Multiphysics 5.6 software. The fluid dynamic and the heat transport profiles between the enclosure and the elliptical cylinder walls are represented by the stream function, isothermal contours, and average Nusselt number. Results estab­lished that for all the considered aspect ratios, the thermal heating range of 103 ≤ Gr ≤ 104 is predomi­nantly a conduction mechanism. The critical position of the ellipse where the inclination effect becomes insignificant is determined by the Grashof number and aspect ratio when the Re = 100. The strength of vortices and cell numbers are significantly influenced by the aspect ratio, particularly when the Gr =104 . When AR =1.0, the average heat transfer from the cylinder remains the same regardless of the cylinder's orienta­tion. The impact of cylinder orientation on heat transfer from the cylinder wall is minimal for 1.5 ≤ AR ≤ 2.0. For AR values of 2.5 ≤ AR ≤ 3.0, increasing the inclination angle does not result in improved heat transfer. The influence of the increasing inclination angle on the right wall diminishes as the angle increases, except when the Grashof number is greater than 105, where the rate of heat transfer is enhanced for inclination angles beyond 45°.
dc.identifier.otherDOI: 10.1002/htj.22907
dc.identifier.urihttps://kwasuspace.kwasu.edu.ng/handle/123456789/283
dc.language.isoen
dc.publisherWiley
dc.titleParametric studies of mixed convective fluid flow around cylinders of different cross‐sections
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Parametric study of mixed convective fluid flow around cylinders of different cross-sections.pdf
Size:
8.84 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: