Inception V3 Based Approach for the Recognition of Age-related macular degeneration Disease.
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Published by Institute of Electrical and Electronics Engineers (IEEE).
DOI
Abstract
Millions of people around the world are infected with age-related macular degeneration (AMD) disease. It is not easily detected in the intermediate stage, as it is typically asymptomatic. Moreover, the ideal learning trends for AMD professional advice are identifying those who are at this stage of the condition, instructing them on ways to screen the early diagnosis of the choroidal neovascular level before significant vision loss is incurred, and encouraging them to think about taking nutritional supplements that may lessen the likelihood that the condition will extend from the intermediate to the mature phase. However, conventional identification of this disease can be time-intensive and necessitates knowledgeably competent individuals to carry out the task. Since retinal fundus images have proven beneficial in detecting AMD, automated methods for AMD detection from retina fundus images can be developed by applying a novel application of deep transfer learning (DTL) to leverage on the artificial intelligence advances. In this investigation, deep convolutional neural networks (DCNN) specifically trained for automated AMD evaluation were contrasted with deep transfer learning (DTL), a different deep learning (DL) technique that included common characteristics with a diagnostic grader. In order to differentiate between the age-related macular degeneration (AMD) stage and the Normal stage, automated identification was used on a 2-class classification issue. The study proposed using deep learning (DL) models, and compared them to the DTL model. The proposed DTL model with transfer learning approach yielded an accuracy of 96.41%, area under receiver operator characteristics curve (AUC) of 0.9633, precision of 94.24%, specificity of 94.82% and false positive rate (FPR) of 0.0518 on the test dataset, which specified a considerable agreement with the gold standard Age-related Eye Disease investigation data set. Implementing an automatic DTL-founded AMD evaluation from fundus scans can yield outcomes that are on par with human effectiveness. This research confirms that automated techniques could perform a task in the current administration of AMD that is self-sufficient of knowledgeable human graders and could take into account the expenses of inspection or surveillance, availability to medical care, and the evaluation of effective therapeutics that resolve the advancement of AMD.
Description
Keywords
Citation
Ogundokun, R.O., Abdulahi, A. T., Adenike, A. R., Babatunde, A. N. and Babatunde, R. S. (2023)
